電動通(tong)風幹(gan)濕表又稱(cheng)阿斯(si)曼,是壹種(zhong)便攜式的測量空氣溫度和濕度的儀(yi)器(qi),常用(yong)於小氣候(hou)觀測和(he)野外考(kao)察(cha)觀測測(ce)量(liang)空氣溫濕度。
儀(yi)表的合理使(shi)用(yong)尤(you)為(wei)重要(yao),那麽(me)通(tong)風幹(gan)濕表該如何(he)合理使(shi)用(yong)呢?
1、通(tong)風幹(gan)濕表使用(yong)期間核(he)查周期時(shi)半(ban)年(nian)壹次(ci)。通(tong)風幹(gan)濕表宜在無油煙(yan),蒸(zheng)汽(qi)及其(qi)他(ta)腐(fu)蝕性(xing)氣體的環境(jing)中使(shi)用(yong),宜懸(xuan)掛或放置地(di)點(dian)避(bi)免(mian)陽光直射。經常檢(jian)查濕球表上的紗套是否清(qing)潔(jie)。經常註意風扇(shan)的轉(zhuan)動(dong)情況(kuang).經常檢(jian)查通(tong)風器(qi)發(fa)條(tiao)盒(he)的轉(zhuan)動(dong)速度。通(tong)風幹(gan)濕表放置攜帶(dai)要(yao)保持平置狀態,並避(bi)免(mian)劇烈(lie)振(zhen)動(dong)。
2、觀測前(qian),應先(xian)濕潤濕球溫度表的紗套,濕潤紗套的時間夏(xia)季(ji)在觀測前(qian)4分鐘、冬(dong)季(ji)在觀測前(qian)15分鐘(有(you)冰(bing)凍時(shi)應(ying)使(shi)之(zhi)融化(hua)),以(yi)濕潤為準(zhun),觀測前(qian)不能有(you)滴(di)水現(xian)象(xiang),濕潤紗套使用(yong)儀(yi)器(qi)的附(fu)件(jian)玻(bo)璃(li)加水管(guan)、橡(xiang)皮囊(nang)、彈(dan)夾進(jin)行(xing)的:濕潤紗套應用(yong)蒸(zheng)餾水和(he)雨(yu)水,不能用(yong)井(jing)水、泉(quan)水、自(zi)來水:每(mei)觀測壹次(ci)需要(yao)重新(xin)濕潤壹次(ci)。加(jia)水時(shi)儀(yi)器(qi)不得(de)倒(dao)置。
3、濕潤紗套以(yi)後(hou),將通(tong)風器(qi)的發(fa)條(tiao)上緊(jin),上緊(jin)發(fa)條(tiao)時,為防止風扇轉(zhuan)動(dong),上發(fa)條(tiao)前(qian)用(yong)紙(zhi)棒從(cong)排風孔(kong)處輕(qing)輕(qing)插入(ru)用(yong)來止動風扇(shan)。
4、使(shi)用(yong)通(tong)風幹(gan)濕表時,應在觀測前(qian)將通(tong)風幹(gan)濕表懸(xuan)掛好,懸(xuan)掛通(tong)風幹(gan)濕表的地方,應保(bao)證(zheng)儀(yi)器(qi)周圍(wei)的障(zhang)礙(ai)物(wu)距(ju)離溫度表球部(bu)至(zhi)少(shao)0.5米,這(zhe)是為了(le)避(bi)免(mian)障(zhang)礙(ai)物(wu)本(ben)身(shen)的熱輻(fu)射影(ying)響(xiang)到溫(wen)度表的測量值(zhi),操作者應該(gai)遠(yuan)離至(zhi)少(shao)0.5米,快要(yao)讀(du)數前(qian)再接(jie)近(jin):通(tong)風幹(gan)濕表懸(xuan)掛好以(yi)後(hou),必須開始經過(guo)壹定(ding)的時間(夏(xia)季(ji)至少(shao)要(yao)有(you)15分(fen)鐘、冬(dong)季(ji)至少(shao)要(yao)有(you)30分(fen)鐘)以(yi)後(hou),才能開始觀測。
5、工(gong)作時(shi),抽掉紙棒(紙(zhi)棒可(ke)以(yi)用(yong)厚(hou)紙片或(huo)多(duo)層(ceng)薄(bo)紙(zhi)疊(die)成(cheng):禁用(yong)硬物(wu)、金(jin)屬物(wu)),等(deng)通(tong)風器(qi)轉(zhuan)動(dong)了4分鐘以(yi)後(hou)進行(xing)溫(wen)度表的讀(du)數,讀(du)數時眼(yan)睛與(yu)水銀柱(zhu)頂端(duan)呈水平,先(xian)讀(du)取(qu)小數,後(hou)讀(du)整(zheng)數,將(jiang)讀(du)數進行(xing)修(xiu)正(即按2支溫(wen)度表檢(jian)定(ding)證所(suo)列的與標(biao)準(zhun)溫度表比較得(de)出(chu)該表各(ge)整(zheng)100C點(dian)上的修(xiu)正值(zhi),進(jin)行(xing)修(xiu)正,消除誤差),然後(hou)再根據修(xiu)正後的幹(gan)球溫(wen)度和濕球溫度就(jiu)可(ke)以(yi)在氣象(xiang)常用(yong)表(本儀(yi)器(qi)附(fu)有(you)簡(jian)明(ming)溫度查算(suan)表)中查(zha)算出空(kong)氣濕度的值(zhi)或(huo)相對值(zhi)。進(jin)行(xing)讀(du)數時,操作者應站(zhan)在下風向,讀(du)數要(yao)迅速(su)、準(zhun)確。測(ce)定(ding)完(wan)畢,待儀(yi)器(qi)風葉停(ting)止轉(zhuan)動(dong)後,才可(ke)收(shou)放儀(yi)器(qi)。在野外使用(yong)如(ru)風速大於3M/S應在通(tong)風幹(gan)濕表通(tong)風器(qi)的迎風面上套上壹個(ge)風擋。以(yi)防止大於通(tong)風速度的不良影(ying)響(xiang)。
6、通(tong)風幹(gan)濕表使用(yong)時(shi)應整(zheng)潔(jie)無(wu)損(sun),將通(tong)風幹(gan)濕表於兩臺(tai)型(xing)號相同的儀(yi)器(qi)壹起(qi),置於室(shi)內氣流較穩(wen)定(ding)的工作臺(tai)而,4-6分(fen)鐘後(hou)觀察,溫(wen)濕度指(zhi)針(zhen)示值(zhi),如(ru)對比誤差溫度大於等於1'C,濕度小於等於5%。則(ze)判為(wei)合格。如(ru)儀(yi)器(qi)對比誤差較大(da)且(qie)偏差(cha)較大(da)且(qie)偏差(cha)變(bian)動頗(po)繁,則(ze)應停(ting)用(yong)送(song)修(xiu)。
註意事(shi)項(xiang)
在壹次(ci)觀測中,壹個(ge)通(tong)風幹(gan)濕表可(ke)以(yi)用(yong)來觀測幾個(ge)不同高(gao)度的空氣溫度、濕度。當壹個(ge)高度觀測完(wan)畢,移到另(ling)壹高(gao)度時,要(yao)讓其(qi)適(shi)應(ying)環境(jing)約1分鐘後(hou)才能進行(xing)讀(du)數。在觀測讀(du)數時註意壹定(ding)要(yao)待溫(wen)度表的示數穩(wen)定(ding)後才能讀(du)數,並且(qie)在整(zheng)個(ge)觀測過(guo)程中要(yao)保持通(tong)風器(qi)的勻速通(tong)風,如果(guo)通(tong)風器(qi)風扇(shan)轉(zhuan)速(su)有(you)所(suo)減慢(man),就(jiu)要(yao)再加(jia)上發(fa)條(tiao)。此(ci)外,濕球紗布應保持潔(jie)白(bai),註意及時(shi)更換。